Constant voltage charging rectifier systems for standby parallel operation, series THE/THD, according to VDE0510

General

Series for higher voltage or power requirements, designed with semi-controlled thyristor rectifier bridges. Suitable for stand-by parallel operation for charging any lead and stationary nickel-cadmium accumulators.

Standard types/dimensions

Sheet steel housing with front door(s)

Chassis version

Floor cabinet

Redundancy systems

Special version

 

Technical data

CoolingConvection cooling or forced cooling for units with a rated current greater than 80ADC (standard).
Standard equipmentCurrent/voltmeter for the GR output, analog Kl.1% (72*72mm); mains isolating transformer according to VDE 0551; mains/battery/grid fuse; control circuit fuses if necessary; "manual charging stage" for charging open battery systems on request
Options external setpoint setting via resistor or potential-free via computer output; temperature compensation of the charging voltage; adjustment of current and voltage by means of a fine potentiometer on the front of the unit instead of on the controller card (at extra charge); 3-fold switchable voltage level (heavy charging/manual charging); 2-fold switchable current limitation (IU-Ia characteristic)
Power supply 1/N/PE 230V 50Hz +/-10% (others on request at extra charge), cable feed in the standard version from the bottom.
Permissible disturbance variables mains voltage/ frequency fluctuations +/-10%; load changes 0-100
Perm. ambient temperature 0°C - 40°C, at 80% relative humidity, others at extra charge
Installation altitudeMax. 1000m over NN
Characteristic curve IU (DIN 41773)
Short circuit resistanceUnrestricted on the basis of the permissible ambient temperature
max. rippleapprox. 5% rms at rated current without connected battery, additional smoothing as special equipment
Voltage constancy+/- 1%
Power Consistency+/- 2%
Power failure bridging20 ms, for use without accumulator set
Radio interference suppressionA (B, against surcharge)
Ordering informationIf additional equipment is used, the indicated dimensions may increase. If the cable lengths to the DC consumers require particularly high cable cross-sections, please specify. For factory consideration, please inform us of the intended battery type when ordering.

 

    What can we do for you? Just send us an e-mail

    *I agree that the information from the form will be collected and processed for the purpose of responding to the request.

    The data will be deleted once processing is complete. Note: You can revoke your consent for the future at any time by e-mail to info@sinus-leistungselektronik.de. Detailed information on the handling of user data can be found in our >>Privacy policy.

    © 2024 - Sinus-Leistungselektronik GmbH